6 Pneumatic Damper Actuator is recommended for control of outdoor, return air, exhaust, face and bypass, and fan discharge dampers. 5 in. The CD60GS also provides AMCA class 1A leakage rating of 3cfm/ft2 at 1”. Ruskin Fire, Smoke, and combination fire/smoke dampers meet the strict requirements established by the International Fire Code (IFC) and the International Building Code (IBC). FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. g. PRESSURE DROP INFORMATION Performance curves based on AMCA Standard 500 using test setup apparatus figure 5. COMMERCIAL CONTROL, MANUAL, AND. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. angles together at corners of dampers. It locks together without bolts, screws, or rivets that could shake loose. Damper frames Dampers shall be constructed with premium vinyl ester resins suitable for specified. FILES (0) Share this page: 1. Fiberglass Backdraft Dampers. for dampers up to 6 sq. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Actuators & Damper Accessories Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. 081" thick extruded aluminum at approximately 4" c-c spacing. Name. Commercial Dampers. Consult Ruskin or your Ruskin repre-sentative when a damper is to be applied in conditions exceeding recommended maximums. Ruskin Literature. And with Ruskin Expressthese labor saving fire dampers can be shipped tomorrow! FAST Angle One Side Dampers are available in sizes and styles that meet your specific job requirements. Ruskin manufactures a complete line of louver models available for both standard and special needs, such as high-volume airflow, wind driven rain, special architectural shapes, sight proof. Dampers shall be in all respects equivalent to Ruskin Model CD40. Ruskin FAST and PFMA are 20 guage steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. Damper Dia. 25" w. 7476 Fax: 816. These louvers are popular for warehouse applications and other structures in which you want to close the airflow without the use of a damper. MINIMUM SIZE Vertical Installation – 4"w x 4"h (102 x 102). Ruskin® Labor Saversfor fire and fire/smoke dampers include factory sleeves, PFMA mounting angles, and tagging by floor or by area. We service the Mechanical Contractor and Mechanical Engineering community in Southern California. 5 illustrates a plenum mounted damper. Counterbalance weights that can be set to relieve air pressure differentials less than . All calculations are with external mounted actuators and accessories. Fasteners and Multiple Section Assembly When joining multiple damper assemblies or fastening the damperThe S2SS Backdraft damper has a 2" frame. Each has added features that enable them to meet all high temperature, high pressure airflow. The EFL closes and locks the damper when temperatures exceed 165°F (74°C)Ruskin FDR25SS is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. 1. Learn more about the FSD60 and its installation instructions from this document. Note: Multiple section dampers are not intended to be structural supports. Airfoil blades, which have greater strength, less static pressure, superior sealing. Page 1 INSTALLATION SUPPLEMENTS Horizontal Installation – 90"w x 91"h (2286 x 2311) or 114"w x 38"h. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. The ELBD375E Automatic Exhaust Dual Combination aluminum louver combines a drainable blade louver and an exhaust backdraft damper in a nominal 6” frame depth. Issue ‘E’ Fuse Link 4. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Higher temperature ratings available consult Ruskin. Automatic Balancing Dampers. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. 15/1, Moo 9, Kabinburi Korat Road, Prachinburi 25110 Thailand. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. Fire/smoke dampers must be installed so the leading edge of the closed blades are within the barrier it is intended to protect (unless specifically designed for out of wall or floor applications). When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. (1. The CD51 is structurally designed for velocities to 2000 fpm. 5hr Static Fire Dampers » 3hr Static. 5 Hour. The bubble tight isolation damper shall be manufactured in an ISO9001 certified factory. FILES (0) Share this page:Energy Recovery Ventilators. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Actuator can be field converted to power open and spring or "fail" closed. Masonry/Wall or Floor: #10 s elf-tapping concrete screws. When you need to "dial in" branch air flow, Ruskin Model VFBD35 Value Flo "IRIS" Balancing Damper is well suited for ease of installation and labor savings. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. Ruskin Green Products. Higher velocities are not recommended for outside air openings, due to water penetration concerns. used in conjunction with Ruskin fire/smoke dampers. Sun Control Sunshades. Commercial Control Damper CD60. Example: Maximum design total pressure of 8. lbs. It features: Fire and heat protection where HVAC components penetrate the ceiling membrane. 01" w. Pressure drop and free area may vary. The pressure drop is the point at which the horizontal,. of 8. Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). The airfoil blades are designed for HVAC systems with velocity and pressures up to 4,000 fpm and 8" w. Built from strong materials and designed on state-of-the-art. 075 lb/cu ft air. 2. Damper Sleeve Sleeve thickness must be equal to or thicker than the duct con-nected to it. Ruskin August 2020 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Multi-section Dampers Dampers over the maximum single section size will require multiple damper sections, typically built in equal sizes. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. to. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. When joining multiple damper assemblies or fastening the damper to the sleeve, dampers shall be fastened with 1/4-20 (M6) bolts, number 10 (M5) screws, or 1/2" (13) long welds stag-gered intermittently on both sides. 2 and can be equipped with factory-mounted actuators. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. — Ruskin ® announces three new emergency generator inlet dampers (GenSet) designed to quickly open to relieve combustion air. CFD7T - 2"x4" Truss Assemblies (Ref. static pressure. FILES (0) Share this page: Catalog. The damper shall be rated for dynamic closure at 2000 fpm (10. Damper shall be Ruskin model PVC12. • Kansas City, MO 64030 • (816) 761-7476 vFBD35 IRIS BALANCINg DAMpER Ruskin IRIS Balancing Damper model VFBD35 is an excellent solu -For other damper sizes refer to Air Performance Data For All Smoke Dampers spec sheet. Our dampers are ideal for outdoor air applications that require low leakage or heavy duty industrial needs to prevent hot or cold outside air penetrating your building. angles together at corners of dampers. Damper locks together without bolts, screws, or. Maximum rating of 4,000 fpm and 8" w. They also offer a new coupler option that joins two damper sections without a jackshaft allowing an actuator to be mounted on side of frame to provide a narrow profile when space is limited. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 ® Nominal Diameter, Inches Total CFM. Complete with 24V modulating actuator and field wired wall mounted, the thermostat gives individual control to office spaces with single or multiple branch ducting. The 316SS construction offers excellent corrosion resistance. static pressure. Must be installed in the factory. RUSKIN provides most finishes available to architects and engineers. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowShare this page: Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. Learn more about the features and. ©Ruskin October 2007 ® Spec FSD60-C-1007/Replaces FSD60/36-C-1206 APPLICATION The FSD60-C is two dampers in one. Model CFM Static Pressure Throw In Feet Neck Velocity Jet Velocity Noise Level. When used in fan discharge applications, damper should bethe damper frame. the application of firestopping caulk in the annular space surrounding a fire or fire/smoke damper <b>is not. Do not weld or fasten angles together at cor-ners of dampers. the damper/sleeve. MAXIMUM SIZE Single section Vertical Installation DIBD2 - 32"w x 36"h (813 x 914). Linkage shall be concealed, out of airstream, within the damper frame to reduce pressure drop and noise. Masonry/Wall or Floor: #10 self-tapping concrete screws. Ruskin smoke damper and actuator assemblies qualify. The CBD2 is an extremely sensitive gravity operated backdraft damper. Ruskin furnishes, installs, and factory commissions actuators from a diverse lineup of manufacturers offering 2-position, 3-position, or modulating control. These dampers are commonly used for vapor cloud and dust cloud explosions found in petroleum, chemical, defense, government, dust collector,. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. This model offers the lowest AMCA leakageRuskin® is an authority in Air Distribution and Air Control products such as dampers, louvers and silencers. g. DaMpER aSSEMBliES The MD35 is intended to be self supporting only in its largest single section size. g. SP200 Switch Package to allow remote indication of damper blade position. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. The FD35/OW, FD35SS/OW and FD60/OW static fire dampers are for use in static (fans off) systems only. It features: AMCA Class 1A leakage for energy savings R value – 2. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. 3. Ruskin "pressure relief" style purge dampers are designed specifically to provide additional make-up air to incineration sys-tems prior to fan start-up. a. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. Model ZCRD25 can also be supplied with Ruskin Cable drive systems. A change anywhere is a change everywhere, instantly!2. Multiple section dampers are available in unlimited sizes. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. Rep Login (817) 509-2300 [email protected] you are looking for a thermally efficient damper that can reduce energy costs and prevent condensation problems, you may want to check out the Ruskin model TED50. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Autodesk®Revit® is Building Information Modeling (BIM) at its best. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. FSD35 FSD36 FSD60 CDO25 CDO25 CD35 CD36 CD50 CD60. Their line includes duct smoke. Conservative ratings are pre - sented intentionally in an effort to avoid misapplication. 2. ©Ruskin 2000 3900 Dr. 765. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. 1. lbs. pressure) for 15 minutes. Torque applied holding damper closed at 10 in. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. g. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. 5 hr. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. Ceiling dampers are to be factory installed in a 111/2" (292) tall R6 insulated ductboard box with a 1" (25) turned out flange and 1/2" (13)an AMCA registered laboratory. com . Unlike other ceiling. A 1" (25) diameter jackshaft is normally used for. Opposed blade dampers must be operated from a power blade on the. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. Find the pressure drop across a 18" wide x 18" (457 x 457) high Model CD80AF4 control damper. g. DAMPER SIZESUnderstanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. 3. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Ruskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. primary fire dampers DO NOT provide the necessary protection. Static pressure and CFM are corrected to. Dampers shall be Ruskin model FSDR25. Multiple section damper assemblies may require brac - ing to support the weight of the assembly and to hold against sys - tem pressure. Ruskin model CD50IF offers HVAC design engineers an ultra-low leak high performance damper which provides: AMCA Class 1A leakage for energy savings Integral 1 ½” flange (front or rear) Mechanically fastened blade edge seals for longevity Shake proof linkage for low maintenance. O. “Out Of Wall” Grille Access Fire Dampers 1 1/2 Hour UL555 Rated | For Dynamic & Static Systems DIBD2GA are dynamic fire dampers designed for “out of wall” applications. Ruskin’s optional wireless damper Inspector™ , utilizing wireless communication protocol by EnOcean®, is the ideal solution for mandatory testing of motorized life safety dampers per NFPA* and Building Code requirements. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/Steel Stud Wall: #10 screws. The Ruskin Wireless Inspector™ includes the RFDI (Radio Frequency Damper Interface) located at each damper withCeiling Fire Dampers UL Classified Radiation Dampers for Wood Truss Construction The CFD7T is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586,. Ruskin provides perfect control Fire Smoke Dampers. The CD40 Series has 6" wide V-grooveThe PFL is a UL Classified heat responsive device used in conjunction with Ruskin fire/smoke dampers. It features a galvanized steel frame, single skin blades, and a variety of actuator options. Higher velocities are not recommended for outside air openings, due to water penetration concerns. Ruskin’s low leak control dampers can save building owners up to $30 per damper 1 annually by providing tight sealing of outside air openings. Closes and locks the damper via a standard replaceable fuse link when the specified temperature is is detected. L586) Ceiling fire dampers maintain the integrity of fire resistive ceiling assemblies constructed from wood Factory or field supplied plenums Assembly designed to accept grilles with up to 2 1/2" grille depth with OBD Through ceiling. Dampers shall be in all respects equivalent to Ruskin Model CD40. The SDRS25 is a UL555S Classified round smoke damper. Ruskin Literature. Ruskin's Commercial Control Dampers provide superior air control, high performance, and sustainable energy efficiency. STATIC PRESSURE IN IN. These combination fire and smoke dampers are designed for installation with the blades running horizontally. 2. Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. 3. Email. The CD60 offers sturdy, steel construction with an interlocking frame design, enabling it to lock together without bolts, screws, or rivets that could shake loose. be-csd-thailand@jci. The damper is rated for Ruskin CD50DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Air Measuring Station with Integral Damper: 15" 300-5000: Transducer (LCD Display Optional) Optional: 3%: W 6" H 6" W 60" H 72" Velocity Pressure:. cheng@jci. The damper shall be rated for dynamic closure at 2000 fpm (10. Certain actuators in Table 1 are UL Recognized Components under. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. It also features: Frame corners that are internally braced to reduce racking. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and an EP (electro/pneumatic) switch. Fire dampers used for the protection of openings in walls, partitions, or masonry floors with fire resistanceThe CFD7T-SB is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. 350° Horizontal FSD36LP 36"x 14" 4"w. Ruskin triple V blade fire/smoke dampers do meet the 3000 fpm, 4" w. ft. back pressure depending on damper size. g. When equipped with blade seals, provides positive shut-off. So turn “on” to energy savings while your building is“off” and let Ruskin start saving you money today. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. R8039)<o:p></o:p> Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Curtain type. 3. lbs. g. Shop custom order Ruskin Dampers and Airflow products for your HVAC needs. Ruskin has a comprehensive line of air measuring, IAQ (Indoor Air Quality), and control solutions. Spec CBD4-507/Replaces CBD4-92000 ©Ruskin 2007 *Unit furnished approx 1/4" (6). Masonry Wall or Floor: #10 s elf-tapping concrete screws Wood/Steel Stud Wall: #10 screws. The EFL is standard on all fire/ smoke dampers ordered with electric actuators. into damper blade and not a secondary operation. This highly functional “true round” backdraft damper eliminates the need for transitions when flange-mounted to round duct installations and is fitted with a counterbalance assembly that canRuskin May 2020 Page 1 CFD4 Ceiling Fire Damper UL Classified Radiation Dampers. Maximum rating of 2,000 fpm and 4" w. static pressure. Ruskin September 2021 Page4 CONSTRUCTION & DIMENSIONAL INFORMATION Ruskin CD50GS is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the. L501). They are designed to be installed inside duct work rather than flange mounted. Mounting Angle Fasteners Sleeve: #10 bolts or screws, 3/16" (3) steel rivets or 1/2" (13) long welds. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy. Every damper is built with performance in mind and tested per AMCA standards. NOTE: Dampers may tolerate higher pressures and velocities than those listed here. The IBDT carries a 1 1/2 hour UL fire damper label and is classified as a static damper for use in HVAC systems that shut down during a fire. Horizontal Installation – 6"w x 6"h (152 x 152). Noise Control. The FDR25SS is rated for maximum velocity of 2,000 fpm and 4” w. It features: Galvanized steel construction. The most effective method of energy-saving insulation. Dampers above 18" (457) – 10 gage steel (3. Select from manual cable drive control to fully automated pressure depended and pressure independent. Greaves Rd. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. Catalog. com. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowRuskin - Dampers Louvers (816) 761-7476 Subject: The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. FILES (0) Share this page: Constructed of premium vinyl ester resins, Ruskin’s fiberglass airflow control products are ideal for installations in corrosive environments such as waste water treatment, micro-electronics fabrication, pulp and paper mills, air pollution control systems and corrosion resistant air exhaust and. II-FSD36-0121/ Replaces II-FSD36-514 ©Ruskin January 2021 ® APPLICATION The FSD35, FSD36 and FSD37 are combination fire and smoke dampers designed to restrict the passage of flame and resist the passage of smoke. Face and by-pass. DIBD2GA fire dampers are idealAMCA Publication 500. Use "Mount With Arrow Up" label as a guide for proper damper orientation. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. back pressure depending on damper size. of damper with minimum of 20 in. G Bolt Circle Diam. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). g. II. 0) sleeve. A complete line of damper products for fire and smoke control in life safety systems and for airflow control in commercial HVAC and industrial systems. Butterfly blade. Louver blades are . Commercial dampers provide low-pressure openings with excellent pressure-drop performance. Aluminum construction. Ruskin CFD model ceiling fire dampers provide the appropriate protection needed for openings in fire rated ceilings. Ceiling Fire Dampers UL Classified Radiation Dampers for Wood Joist Construction The CFD7 is a UL Classified Ceiling Fire Damper that is UL approved for installation in ceilings constructed from wood joists. 2 m/s) and 4” w. ©Ruskin 2000 3900 Dr. Stainless Steel Construction See model (D)IBD2SS. Ruskin pressure drop testing was conducted in accordance with AMCA Standard 500-D using Figure 5. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. , Ruskin does not recommend using these designs in systems with velocities greater than 2000 fpm. g. Standard features vary by model to make application selection straightforward. Our plant in Thailand is well-equipped to manufacture next-generation products. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. The CD80AF2 Industrial Control damper has an 8" frame. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowThe FSD60V Combination Fire/Smoke Damper is both UL555 and UL555S Classified. 25" w. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. Mounting Angle Fastener Spacingon dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. b. Look for the AMCA Labeled products to be sure you are getting the performance you require. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. Relief doors open automatically to prevent ductwork from imploding or exploding due to differential pressure. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. As an option, qualification for use in Nuclear. Specifier Select Option Dampers shall be equipped with factory installed damper. 75" w. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. INSTALLATION For proper operation, damper must be installed square and free from racking. Phone. The switch package shall include two position indicator switches linked directly to the damper blade to provide full open and full closed damper blade position. FILES (0) Share this page: Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. c. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. Swartwout series model 914 Heavy Duty Fiberglass Round Control Damper • Accurate control of airflow through the round duct • Designed specifically for corrosive environments • Premium constructed Vinyl Ester, Flange Mounted, single piece blade has 3 frame styles • Designed to withstand pressures up to 30" wg Differential PressureRuskin's premier damper for medium pressure commercial and industrial HVAC systems offers the lowest leakage available with a standard, commercial built damper. The damper frames are made of galvanized steel in a channel frame construction, offering an equivalent 13-gauge metal strength. The CD35 commercial control damper offers sturdy, steel construction with interlocking frame design. Find the conversion velocity (CV) by multiplying the selected size damper's area factor by the flow rate in CFM: CV = Area Factor x CFM 3. Models CD36, CD35, IL35, CD40 and CD403, 4". The CFDR2 is a UL555C Classified Round Ceiling Fire Damper. Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. The CD60GS is designed to provide maximum combustion air and pressure relief quickly for emergency generator start up to avoid damage of equipment orsurrounding space. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. Welcome to Ruskin Rooftop Systems. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. added to the damper at fabrication. Select the damper size. a. Actuators are designed to operate reliably in smoke control systems requiring Underwriter’s Laboratories, Inc. Ruskin CFD(R)2 and CFD(R)3 are UL Classified to provide protection to HVACRectangular Steel V-Groove. Static only damper labels are not permissible. Greaves Rd. RectangulaR DampeRs CD40, CD50, CD60 SerieS DeSCripTiOn The ruskin CD40, CD50, CD60 parallel and opposed-blade HVAC control dampers are custom made-to-order. Greaves Rd. Dampers can be constructed of galvanized, stainless, or aluminum and are available with a diverse compliment of. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. Damper shall be in all respects equivalent to Ruskin BD6. Space fasteners 6" (152) on center and a maximum 2" (51) from the ends of the joining sec-tions or from each corner. Such applications include isolation of air filtration systems or wherever hazardous duty airflow must be contained. Learn about their history, products,. D-DIA. 025" thick formed aluminum with concealed blade linkage, synthetic bearings and non. Maximum Damper Width (A Dimension) Maximum Damper Width (A Dimension) AREA FACTOR TABLE EXAMPLE: 1. The DIBD20, 40, 60 carry a 1 1/2 hour UL fire damper label and are classified as a dynamic damper for use in HVAC systems that remain in operation during a fire. A. Commercial Dampers; Diffusers; Economizers; Energy Recovery Ventilators; Industrial Dampers; Life Safety Dampers; Louvers & Architectural; Pressure Relief Doors; Noise. 5 illustrates a plenum mounted damper. All Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. This damper is fitted with a counterweight assembly that can be field adjusted and calibrated to meet the specific airflow requirements of your unique system. Providing accurate control or isolation of. 2. The factory mounted fast-acting 8-second spring open actuatorprovides optimal performance and reliability. Pressure Relief Doors. Share this page: From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control. It also features: Frame corners that are internally braced to reduce racking. 21. Frame shall be 16 ga. 3. 4 psi respectively. Ruskin Literature. Do not weld or fasten angles together at corners of dampers. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. g. CDRS82 ROUND CONTROL DAMPER Spec CDRS82-102/Replaces CDRS82-193 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Dampers shall be in all respects equivalent to Ruskin model CBD6. 1. com W: Ruskin® manufactures an extensive line of UL-rated and listed dampers to protect your life and property. 6 psi to 44. 5, CFD4 and CFD(R)5 are UL labeled ceiling radiation dampers. 16 (per ASTM C1363-2011) Thermal break in blade eliminates any thermal path, reduces condensation Mechanically fastened blade edge seals for longevity Shake proof. Industrial Fiberglass Louvers. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. 7 %âãÏÓ 69 0 obj > endobj xref 69 77 0000000016 00000 n 0000002434 00000 n 0000002561 00000 n 0000004375 00000 n 0000004685 00000 n 0000005201 00000 n 0000005701 00000 n 0000006313 00000 n 0000006746 00000 n 0000007307 00000 n 0000007930 00000 n 0000007966 00000 n 0000008506 00000 n 0000008619 00000 n. g. Ruskin fire/smoke dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Refer to the UL approved installation instructions for specific requirements. Details shown do NOT APPLY if your control damper has any of the following fea-tures: 1. • Sealing durability in. Unlike conventional mounting angles that can-not be fastened together in the corners and ship separately from the dampers, the FAST and PFMA are: • One piece angles (fastened together in the corners)- Single section dampers ordered with either 12” (305), 14” (356) or 16” (406) long sleeve; the IBD20, 40, 60, 230, 430 and 630 models may be substituted.